MTI Instruments AccumeasureÊý×ÖµçÈÝϵͳDϵÁÐGen 3
·¢²¼Ê±¼ä£º2021-03-15 17:15:58 ä¯ÀÀ£º1191
MTI Instruments AccumeasureDµçÈÝÊ½Î»ÒÆ´«¸ÐÆ÷ϵÁзŴóÆ÷ÊÇÒ»¸ö¸ïÃüÐÔµÄÉè¼Æ·½°¸¡£ËüÔËÓÃÍ»ÆÆÐÔ¼¼Êõ£¬½«¸ß¿É¿¿µÄµçÈݵ糡¼ì²â£¨Î»ÒÆ£©Ö±½Óת»¯³É¸ß¾«¶ÈµÄ24λÊý×Ö¶ÁÊý£¬´Ó¶ø¾«È·²âÁ¿Î»Öᢺñ¶È¡¢Ô˶¯ºÍÕ𶯡£
MTI InstrumentsµÄÐÂÐ͵çÈÝ·Å´óÆ÷½«Ì½Í·µçÈÝÖ±½Óת»»³ÉΪĿ±ê¼ä¾à£¨¾àÀ룩¡£ÕâÀàÖ±½Óת»»·½·¨Ïû³ýÁË´«Í³Ê½Ä£Äâ·Å´óÆ÷¼øÓÚÄ£ÄâÂ˲¨¡¢ÏßÐÔ»¯¡¢·¶Î§ÍØÕ¹ºÍͨµÀÇóºÍ¶øÔì³ÉµÄÎó²îÖµ£¬´Ó¶ø»ñÈ¡ºñ¶È»ò½×Ô¾¼ì²âÖµ¡£Æ¾½èAccumeasure DϵÁУ¬¶ÔÂ˲¨Æ÷µÄƵÂÊÏìÓ¦¡¢²ÉÑùÂÊ¡¢ÏßÐÔ»¯ºÍ̽ͷ·¶Î§ÊµÏÖÁËÊý×Ö¿ØÖÆ¡£ÕâÈ·±£ÁË×î׼ȷµÄÊý¾Ýץȡ¡¢ÎÞËð´¦ÀíºÍ¹ºÂò¶îÍâ²É¼¯Ó²¼þÅäÖõÄ×ÔÓÉȨ¡£
±ê×¼º¯ÊýÕý½»±àÂëÆ÷ÊäÈ룬¸ù¾ÝÎ»ÒÆ²âÁ¿ÖµÓë̽ͷλÖÃͬ²½£¬Ìṩ̽ͷλÖÃÐÅÏ¢ºÍÎ»ÒÆÐźţ¬Ìṩ¸÷ÖÖ¸÷Ñùµ¼µçºÍ°ëµ¼ÌåÄ¿±êµÄ׼ȷ±íÃæÂÖÀª¡£MTI InstrumentsµÄDigital AccumeasureµçÈÝÊ½Î»ÒÆ´«¸ÐÆ÷·Å´óÆ÷±ê×¼ÅäÖÃ24λUSB/ÒÔÌ«ÍøÊý×ÖÊä³ö¡£³ýÈ¥±ê×¼µÄÊý×ÖÊä³öÍ⣬ģÄâÊä³öÄ£ÐÍ»¹°üÀ¨Ä£ÄâÊä³ö¡£Á½ÕßÄܹ»Í¬Ê±ÔËÓá£ÕâÌØ±ðÊʺÏÓÚ±Õ»·Ó¦ÓóÌÐò»ò¼¯³É»¯µ½ÐèҪģÄâµÄ²Ù×÷ϵͳÖС£
ÌØÐÔ
ÕæÕýµÄÖ±½ÓÊý×ÖµçÈÝÎ»ÒÆ´«¸ÐÆ÷
µçÈÝÊ½Î»ÒÆ´«¸ÐÆ÷
¸ß´ï0.01%FSRÏßÐÔ¶È
ÑÇÄÉÃ×·Ö±æÂÊ
ÄÚÖÃÕý½»ÊäÈë
20Ks/s
È«²¿Í¨µÀ
ÎÞADC
¼ä¾àÏìÓ¦µÄ100%Êý×ÖÏßÐÔ»¯
ÎÞËð24λ´¦Àí
ºÍNILabVIEW?½Ó¿Ú
¿Éµ÷Êä³öÊý¾ÝËÙÂÊ
̽ͷÊý×Ö¶¨Ïà
¸¡°Ð¼ì²â
Êý¿Ø·¶Î§ÍØÕ¹¡¢Â˲¨ºÍÐÅºÅÆ½¾ù
USBºÍÒÔÌ«ÍøÊä³ö
Ä£ÄâÊä³ö
ÎÞÐè¶îÍâµÄ²É¼¯Ó²¼þÅäÖÃ
ÉîÛÚÊÐÁ¢Î¬´´Õ¹¿Æ¼¼ÓÐÏÞ¹«Ë¾£¬ÓÅÊÆÖ±½ÓÇþµÀÌṩMTI Instrument s¶©»õ·þÎñ£¬»¶Ó×Éѯ¡£
ÏêÇéÁ˽âMTI Instrument sÇëµã»÷£º/brand/70.html
»òÁªÏµÎÒÃǵÄÏúÊÛ¹¤³Ìʦ£º0755-83642657 QQ: 2295048674
P/N | Accuracy | Interface | Type | Frequency Response |
8000-6454-100 | 0.01% FSR | USB | 1-channel (SE) | User Selectable 50Hz to 5kHz |
8000-6454-110 | 0.01% FSR | Analog and USB | 1-channel (SE) | User Selectable 50Hz to 5kHz |
8000-6454-200 | 0.01% FSR | USB | 2-channel (SE) | User Selectable 50Hz to 5kHz |
8000-6454-201 | 0.01% FSR | USB | 2-channel (PP) | User Selectable 50Hz to 5kHz |
8000-6454-202 | 0.01% FSR | USB | 2-channel (180) | User Selectable 50Hz to 5kHz |
8000-6454-210 | 0.01% FSR | Analog and USB | 2-channel (SE) | User Selectable 50Hz to 5kHz |
8000-6454-211 | 0.01% FSR | Analog and USB | 2-channel (PP) | User Selectable 50Hz to 5kHz |
8000-6454-212 | 0.01% FSR | Analog and USB | 2-channel (180) | User Selectable 50Hz to 5kHz |
8000-6454-300 | 0.01% FSR | USB | 3-channel (SE) | User Selectable 50Hz to 5kHz |
8000-6454-310 | 0.01% FSR | Analog and USB | 3-channel (SE) | User Selectable 50Hz to 5kHz |
8000-6454-400 | 0.01% FSR | USB | 4-channel (SE) | User Selectable 50Hz to 5kHz |
8000-6454-401 | 0.01% FSR | USB | 4-channel (PP) | User Selectable 50Hz to 5kHz |
8000-6454-402 | 0.01% FSR | USB | 4-channel (180) | User Selectable 50Hz to 5kHz |
8000-6454-410 | 0.01% FSR | Analog and USB | 4-channel (SE) | User Selectable 50Hz to 5kHz |
8000-6454-411 | 0.01% FSR | Analog and USB | 4-channel (PP) | User Selectable 50Hz to 5kHz |
8000-6454-412 | 0.01% FSR | Analog and USB | 4-channel (180) | User Selectable 50Hz to 5kHz |
ÉÏһƪ: TI µÂÖÝÒÇÆ÷µçÁ÷¸ÐÓ¦·Å´óÆ÷Ä£ÄâÊä³ö
ÏÂһƪ: HypertronicsÁ¬½ÓÆ÷KS ϵÁÐ
ÍÆ¼ö×ÊѶ
855B-54 ÐÍÊÇһϵÁÐÏàλÏà¸É¡¢¶àͨµÀ¡¢³¬¿ìËÙ¿ª¹ØºÍ³¬µÍÏàλÔëÉùÐźŷ¢ÉúÆ÷£¬ÆµÂÊ·¶Î§¸ß´ï 20¡¢40 ºÍ 54 GHz¡£Ëü·Ç³£Êʺϸ÷ÖÖÓ¦Óã¬ÕâЩӦÓÃÐèÒªÁ¼ºÃµÄÐźÅÖÊÁ¿¡¢×¼È·ºÍ¿íµÄÊä³ö¹¦ÂÊ·¶Î§£¬ÒÔ¼°ËùÓÐͨµÀÖ®¼ä·Ç³£Îȶ¨µÄÏàλÏà¸ÉÐÔ¡£³öÉ«µÄÏàλÔëÉùÓëÁ¼ºÃµÄÔÓÉ¢¡¢Ð³²¨ÒÖÖÆºÍ¿ÉÑ¡µÄ 15 ¦Ìs Ç°ÑØ¿ª¹ØËÙ¶ÈÏà½áºÏ¡£
MTI Instruments?²âÊÔÉ豸¸ßËÙ¶þά¼¤¹âÂÖÀª´«¸ÐÆ÷ÌØ±ðÊʺÏÓÃ×÷³ß´ç¼ì²â¡¢ºñ¶È¡¢ÂÖÀª¡¢½ðÊô²ÄÁÏÍäÇú¡¢º¸¿Ú¡¢º¸·ì¼à²âµÄÖÊÁ¿¹ÜÀíºÍÉú²úÖÆÔìÓ¦Ó㬲¢ÓÃÀ´×÷Ϊ¼¤¹â¼ä϶¼ì²â¡£
ÔÚÏßÁôÑÔ