MTI Instruments AccumeasureÊý×ÖµçÈÝϵͳDϵÁÐGen 3
·¢²¼Ê±¼ä£º2021-03-15 17:15:58 ä¯ÀÀ£º1536
MTI Instruments AccumeasureDµçÈÝÊ½Î»ÒÆ´«¸ÐÆ÷ϵÁзŴóÆ÷ÊÇÒ»¸ö¸ïÃüÐÔµÄÉè¼Æ·½°¸¡£ËüÔËÓÃÍ»ÆÆÐÔ¼¼Êõ£¬½«¸ß¿É¿¿µÄµçÈݵ糡¼ì²â£¨Î»ÒÆ£©Ö±½Óת»¯³É¸ß¾«¶ÈµÄ24λÊý×Ö¶ÁÊý£¬´Ó¶ø¾«È·²âÁ¿Î»Öᢺñ¶È¡¢Ô˶¯ºÍÕ𶯡£
MTI InstrumentsµÄÐÂÐ͵çÈÝ·Å´óÆ÷½«Ì½Í·µçÈÝÖ±½Óת»»³ÉΪĿ±ê¼ä¾à£¨¾àÀ룩¡£ÕâÀàÖ±½Óת»»·½·¨Ïû³ýÁË´«Í³Ê½Ä£Äâ·Å´óÆ÷¼øÓÚÄ£ÄâÂ˲¨¡¢ÏßÐÔ»¯¡¢·¶Î§ÍØÕ¹ºÍͨµÀÇóºÍ¶øÔì³ÉµÄÎó²îÖµ£¬´Ó¶ø»ñÈ¡ºñ¶È»ò½×Ô¾¼ì²âÖµ¡£Æ¾½èAccumeasure DϵÁУ¬¶ÔÂ˲¨Æ÷µÄƵÂÊÏìÓ¦¡¢²ÉÑùÂÊ¡¢ÏßÐÔ»¯ºÍ̽ͷ·¶Î§ÊµÏÖÁËÊý×Ö¿ØÖÆ¡£ÕâÈ·±£ÁË×î׼ȷµÄÊý¾Ýץȡ¡¢ÎÞËð´¦ÀíºÍ¹ºÂò¶îÍâ²É¼¯Ó²¼þÅäÖõÄ×ÔÓÉȨ¡£
±ê×¼º¯ÊýÕý½»±àÂëÆ÷ÊäÈ룬¸ù¾ÝÎ»ÒÆ²âÁ¿ÖµÓë̽ͷλÖÃͬ²½£¬Ìṩ̽ͷλÖÃÐÅÏ¢ºÍÎ»ÒÆÐźţ¬Ìṩ¸÷ÖÖ¸÷Ñùµ¼µçºÍ°ëµ¼ÌåÄ¿±êµÄ׼ȷ±íÃæÂÖÀª¡£MTI InstrumentsµÄDigital AccumeasureµçÈÝÊ½Î»ÒÆ´«¸ÐÆ÷·Å´óÆ÷±ê×¼ÅäÖÃ24λUSB/ÒÔÌ«ÍøÊý×ÖÊä³ö¡£³ýÈ¥±ê×¼µÄÊý×ÖÊä³öÍ⣬ģÄâÊä³öÄ£ÐÍ»¹°üÀ¨Ä£ÄâÊä³ö¡£Á½ÕßÄܹ»Í¬Ê±ÔËÓá£ÕâÌØ±ðÊʺÏÓÚ±Õ»·Ó¦ÓóÌÐò»ò¼¯³É»¯µ½ÐèҪģÄâµÄ²Ù×÷ϵͳÖС£
ÌØÐÔ
ÕæÕýµÄÖ±½ÓÊý×ÖµçÈÝÎ»ÒÆ´«¸ÐÆ÷
µçÈÝÊ½Î»ÒÆ´«¸ÐÆ÷
¸ß´ï0.01%FSRÏßÐÔ¶È
ÑÇÄÉÃ×·Ö±æÂÊ
ÄÚÖÃÕý½»ÊäÈë
20Ks/s
È«²¿Í¨µÀ
ÎÞADC
¼ä¾àÏìÓ¦µÄ100%Êý×ÖÏßÐÔ»¯
ÎÞËð24λ´¦Àí
ºÍNILabVIEW?½Ó¿Ú
¿Éµ÷Êä³öÊý¾ÝËÙÂÊ
̽ͷÊý×Ö¶¨Ïà
¸¡°Ð¼ì²â
Êý¿Ø·¶Î§ÍØÕ¹¡¢Â˲¨ºÍÐÅºÅÆ½¾ù
USBºÍÒÔÌ«ÍøÊä³ö
Ä£ÄâÊä³ö
ÎÞÐè¶îÍâµÄ²É¼¯Ó²¼þÅäÖÃ
ÉîÛÚÊÐÁ¢Î¬´´Õ¹¿Æ¼¼ÓÐÏÞ¹«Ë¾£¬ÓÅÊÆÖ±½ÓÇþµÀÌṩMTI Instrument s¶©»õ·þÎñ£¬»¶Ó×Éѯ¡£
ÏêÇéÁ˽âMTI Instrument sÇëµã»÷£º/brand/70.html
»òÁªÏµÎÒÃǵÄÏúÊÛ¹¤³Ìʦ£º0755-83642657 QQ: 2295048674
P/N | Accuracy | Interface | Type | Frequency Response |
8000-6454-100 | 0.01% FSR | USB | 1-channel (SE) | User Selectable 50Hz to 5kHz |
8000-6454-110 | 0.01% FSR | Analog and USB | 1-channel (SE) | User Selectable 50Hz to 5kHz |
8000-6454-200 | 0.01% FSR | USB | 2-channel (SE) | User Selectable 50Hz to 5kHz |
8000-6454-201 | 0.01% FSR | USB | 2-channel (PP) | User Selectable 50Hz to 5kHz |
8000-6454-202 | 0.01% FSR | USB | 2-channel (180) | User Selectable 50Hz to 5kHz |
8000-6454-210 | 0.01% FSR | Analog and USB | 2-channel (SE) | User Selectable 50Hz to 5kHz |
8000-6454-211 | 0.01% FSR | Analog and USB | 2-channel (PP) | User Selectable 50Hz to 5kHz |
8000-6454-212 | 0.01% FSR | Analog and USB | 2-channel (180) | User Selectable 50Hz to 5kHz |
8000-6454-300 | 0.01% FSR | USB | 3-channel (SE) | User Selectable 50Hz to 5kHz |
8000-6454-310 | 0.01% FSR | Analog and USB | 3-channel (SE) | User Selectable 50Hz to 5kHz |
8000-6454-400 | 0.01% FSR | USB | 4-channel (SE) | User Selectable 50Hz to 5kHz |
8000-6454-401 | 0.01% FSR | USB | 4-channel (PP) | User Selectable 50Hz to 5kHz |
8000-6454-402 | 0.01% FSR | USB | 4-channel (180) | User Selectable 50Hz to 5kHz |
8000-6454-410 | 0.01% FSR | Analog and USB | 4-channel (SE) | User Selectable 50Hz to 5kHz |
8000-6454-411 | 0.01% FSR | Analog and USB | 4-channel (PP) | User Selectable 50Hz to 5kHz |
8000-6454-412 | 0.01% FSR | Analog and USB | 4-channel (180) | User Selectable 50Hz to 5kHz |
ÉÏһƪ: TI µÂÖÝÒÇÆ÷µçÁ÷¸ÐÓ¦·Å´óÆ÷Ä£ÄâÊä³ö
ÏÂһƪ: HypertronicsÁ¬½ÓÆ÷KS ϵÁÐ
ÍÆ¼ö×ÊѶ
RFSL2601ÊÇÒ»¿î¸ß¹¦ÂʸôÀëÆ÷£¬¹¤×÷ƵÂÊ·¶Î§Îª1930ÖÁ1995 MHz£¬ÊÊÓÃÓڶԸ߸ôÀë¶ÈºÍµÍ²åÈëËðºÄÓÐÒªÇóµÄÉ䯵ӦÓá£ÆäµçÆø¹æ¸ñ°üÀ¨£º²åÈëËðºÄСÓÚ0.20 dB£¨×î´ó0.30 dB£©£¬¸ôÀë¶È×îС22 dB£¨µäÐÍÖµ´óÓÚ25 dB£©£¬»Ø²¨ËðºÄ×îС22 dB£¨µäÐÍÖµ´óÓÚ25 dB£©£¬5MHz¼ä¸ôΪ75 dBc£»¹¦ÂʺÍζȵȼ¶·½Ã棬ÕýÏò¹¦ÂÊ·åÖµ/ƽ¾ùֵΪ1000/200W£¬·´Ïò¹¦ÂÊÁ¬Ðø²¨Îª20W£¬Öն˶¹¦ÂÊ20W£¬¹¤×÷ζȷ¶Î§ÊÇ -40¡ãCÖÁ +85¡ãC£¬´æ´¢Î¶ȷ¶Î§ÊÇ -40¡ãCÖÁ +95¡ãC ¡£
865B-M-40-XÐÍºÏ³ÉÆ÷ÊÇÒ»¿î¸ßÐÔÄÜ΢²¨/É䯵ÐźÅÔ´£¬ÆµÂÊ·¶Î§100 kHzÖÁ43.5 GHz£¬¾ßÓÐ2»ò4¸ö¶ÀÁ¢Í¨µÀ£¬¿É¶ÀÁ¢ÅäÖÃÆµÂÊ¡¢¹¦ÂʵȲÎÊý¡£Ö§³Ö¶àÖÖ±à³ÌÓïÑÔ¿ØÖÆ£¬ÊÊÓÃÓÚ×Ô¶¯»¯²âÊÔ¡¢ÎÞÏßͨÐŵÈÁìÓò£¬¾ß±¸¿ìËÙÇл»ºÍ¶àÖÖµ÷ÖÆ¹¦ÄÜ¡£